Smart PDU Firmware Downloads
VPD, VPS, VPM, and VPO SERIES FIRMWARE
Download the latest firmware version:FIRMWARE LAST VERSION
Steps for upgrade firmware after file download:
1. Install SNMP on Advanced - Maintenance menu- Firmware Update
2. Unzip the file and install on Advanced - Inlet & Outlet upgrade
FIRMWARE HISTORY
Revision History
Date | Component | Revision | Description |
2024/03/29 | SNMP Board | 0.40a13-3 |
1. To add “support SNMP v3 only feature” 2. To release MIB file v1.02 |
2024/03/27 | Inlet/Outlet | 1.0.29 |
1. To fix outlet webpage display lag problem when turn on/off process. 2. To change AC voltage detection rule for DIP voltage test. |
2024/02/23 | SNMP Board | 0.40a08 |
1. To fix SNMP client query following alarm status reporting error. pduDevMonInletEvtLoadBalance, pduDevMonInletEvtOverLoad, pduDevMonInletEvtStatusPh1 ~ 3 |
2024/02/22 | SNMP Board | 0.40a07 |
1. To change common name to vericomsolutions.com. 2. To add removing certificate function on the Security page. 3. To fix energy was reset to 0 after system restart. |
2024/02/21 | SNMP Board | 0.40a06 | 1. To change certificate subject according to Vericom requirements. 2. To fix Inlet and Outlet value during power share startup. |
2024/01/25 | SNMP Board | 0.40a04 | 1. To fix netmask and route address conflict problem. |
2023/11/24 | SNMP Board | 0.30 a59 |
1. Add Serial Number in General Setting webpage. 2. Add MAC address in TCP/IP webpage. 3. Change LCM’s daisy chain PDU display name. 4. Change Load Balance max. threshold from 200 to 400. 5. Fix email cannot send issue. |
2023/11/24 | Inlet / Outlet | 1.0.25 | 1. To fix some RCMB (DC type) incorrect actions. |
2023/10/13 | SNMP Board | 0.30 a57 |
1. Modify firmware to support dual ethernet Standalone mode. 2. Update SPS2_MIBv1_v0.98 and SPS2_MIBv2_v0.98 file for dual ethernet Standalone mode support. 3. Fixed issue where uploaded language would disappear after system restart. |
2023/09/11 | Inlet / Outlet | 1.0.24 | 1. To fix outlet switching problem when breaker turn off in the POS system. |
2023/08/31 | SNMP Board | 0.30 a55 | 1. To fix outlet energy has not matching between SNMP v2 and Webpage. |
2023/08/31 | Inlet / Outlet | 1.0.23 | 1. To fix outlet energy has not matching between SNMP v2 and Webpage. |
2023/08/18 | SNMP Board | 0.30 a54 | 1. To fix daisy chain problem that sometimes slaves PDU will disappear in the webpage. |
2023/08/18 | Inlet / Outlet | 1.0.22 | 1. The Inlet board support 16A CT system assembly by Vericom system request. |
2023/08/10 | SNMP Board | 0.30 a53 |
1. To fix daisy chain problem that sometimes slaves PDU will disappear in the webpage. The total length of the daisy chain will be 20 meters for 16pcs PDU. 2. To fix the network instability problem that enhance dual Ethernet mode solution. |
2023/06/30 | SNMP Board | 0.30 a51 | 1. Remove “Type” from Inlet Display screen of the DFSTN LCM and OLED. |
2023/06/20 | Inlet / Outlet | 1.0.21 | 1. To fix sequential startup abnormal and outlet disappear problem in the POS system. |
2023/06/13 | Inlet / Outlet | 1.0.20 | 1. To fix sequential startup abnormal and outlet disappear problem in the POS system. |
2023/06/07 | Inlet / Outlet | 1.0.19 | 1. To fix volts abnormal display of the inlet L2&L3. |
2023/05/26 | SNMP Board | 0.30 a50 |
1. Fix parameters crash problem. 2. Add SNMPv3 USM table MIB file. 3. If system name is default value (default:PDU), then DHCP hostname attached with system name and mac address, otherwise, only attached system name. 4. Change system name default value from Powertek to PDU. (Only at first time upgrade to this version will working, ex. Upgrade from TI MFG FW to this version). 5. Change LCM type default value from STN to OLED. (Only at first time upgrade to this version will working, ex. Upgrade from TI MFG FW to this version). 6. Change PDU Type default value from 3 phase PDU 250V 32A to 3 phase PDU 380V 32A. (Only at first time upgrade to this version will working, ex. Upgrade from TI MFG FW to this version). 7. Release new MIB file SPS2_MIBv1_0.97.mib and SPS2_MIBv2_v0.97.mib. |
VPN SERIES FIRMWARE
Download the latest firmware version:VPN FIRMWARE LAST VERSION
Steps for upgrade firmware after file download:
1. Install VPN SNMP on Advanced - Maintenance menu- Firmware Update
2. Unzip VPN Inlet Upgrade File and install on Advanced - Inlet & Outlet upgrade
FIRMWARE HISTORY
— Revision History
—
— v0.10 09-Dec-2020 Grace Wu Created
—
—
— v0.20 05-Feb-2021 Kenneth change OID to simple(2) for pwt(4)
—
—
— v0.30 20-Feb-2021 Grace Wu
— 1. pduEmdCurrInfoHumidityStat SYNTAX INTEGER change to normal(1), warning(2),critical(3).
— 2. pduEmdCurrInfoTempStat SYNTAX INTEGER change to normal(1),warning(2),critical(3).
— 3. pduEmdCfgEMDAddress change to read-only.
— 4. pduEmdCfgAppFWVer change to read-only.
— 6. pduEmdCfgTempCalOffset SYNTAX INTEGER change to fivePointFour(1),fourPointFive(2),
— threePointSix(3),twoPointSeven(4),onePointEight(5),zeroPointNine(6),zeroPointZero(7),
— negativeZeroPointNine(8),negativeOnePointEight(9),negativeTwoPointSeven(10),
— negativeThreePointSix(11),negativeFourPointFive(12),negativeFivePointFour(13).
— 7. pduEmdCfgHumidityCalOffset SYNTAX INTEGER change to six(1),five(2),four(3),three(4),two(5),
— one(6),zero(7),negativeOne(8),negativeTwo(9),negativeThree(10),
— negativeFour(11),negativeFive(12),negativeSix(13).
— 8. pduDateAndTimeNtpSyncIntervalType change day to 1, month to 2.
— 9. pduIecViewMgmtGuid change to read-only.
— 10. pduAccessIpSettingTblAction accept->allow,reject->deny.
— 11. pduEmdCfgTempCritHigh SYNTAX INTEGER change to 0..650.
— 12. pduEmdCfgTempCritLow SYNTAX INTEGER change to 0..650.
— 13. pduEmdCfgTempWarnHigh SYNTAX INTEGER change to 0..650.
— 14. pduEmdCfgTempWarnLow SYNTAX INTEGER change to 0..650.
— 15. pduNetServiceRadiusTimeout SYNTAX INTEGER change to 1..99.
— 16. pduNetServiceRadiusRetry SYNTAX INTEGER change to 1..99.
— 17. pduSnmpSettingTrapEvtLevel SYNTAX INTEGER change to informational(1),warning(2),critical(3).
— 18. pduEmailSettingSmtpAuthEn SYNTAX INTEGER change to disabled(1),enabled(2)
— 19. trap change some description.
—
—
— v0.40 22-Feb-2021 Grace Wu
— 1. pduIpv6SettingAddress change to pduIpv6SettingLocalAddress and change to read.
— 2. add pduIpv6SettingGlobalAddress.
— 3. pduIpv6SettingPrefix range change from 0-63 to 0-128
—
—
— v0.50 04-Mar-2021 Grace Wu
— 1. pduCfgCritOverLoadAlm unit changet to 0.1W, and range change to 0-140800.
— 2. pduCfgCritLoadBalanceAlm unit changet to 0.1%, and range change to 0-1000.
— 3. pduCfgWarnOverLoadAlm unit changet to 0.1W, and range change to 0-140800.
— 4. pduCfgWarnLoadBalanceAlm unit changet to 0.1%, and range change to 0-1000.
— 5. pduEmdCurrInfoHumidityValue unit changet to 0.1%.
— 6. pduEmdCfgTempCritHigh add unit 0.1.
— 7. pduEmdCfgTempCritLow add unit 0.1.
— 8. pduEmdCfgTempWarnHigh add unit 0.1.
— 9. pduEmdCfgTempWarnLow add unit 0.1.
— 10. Critical: Cold boot. -> coldStart.
— 11. Critical: Warm boot. -> warmStart.
— 12. add trap pduInletCurrCB2Phase1Warn(71)~pduInletCurrPhase3CB2CritToWarn(82).
— 13. trap pduInletCurrPhase1Warn(15)~pduInletCurrPhase3CritToWarn(26) name add CB1.
—
—
— v0.60 12-Mar-2021 Grace Wu— 1. remove pduIpv6SettingPrefix.